Close
Online message
If you have any needs, please leave a message and we will contact you as soon as possible¡£

¡¤ High efficiency
¡¤ Small size and light weight
¡¤ Accurate flow distribution
¡¤ Low pressure loss, saving fuel consumption
¡¤ Fast response speed
EHV06
? ЧÂʸß
? Ìå»ýС£¬ÖØÁ¿Çá
? ¾«È·µÄÁ÷Á¿·ÖÅÉ
? ѹËðµÍ£¬½ÚÊ¡ÓͺÄ
? ÏìÓ¦Ëٶȿì
EHV09/09S/18
? ²Ù×÷е÷ÐԸߣ¬Ð§Âʸß
? ½á¹¹½ô´Õ£¬ÖØÁ¿Çá
? ¾«È·µÄ¿ØÖÆ£¬Î¢¶¯ÐÔºÃ
? ѹËðС£¬ÓͺĵÍ
? ÊæÊʵÄÀûÓÃÐÔ
Nominal size | EHV06 | EHV09P | EHV09S | EHV18 | |
General | |||||
Structure | Stackable, load sensing, post pressure compensated | Stackable, proportional, load sensing, pre-compensated | |||
Type of connection | ISO BSP thread, metric thread | ISO1179-1 | JISB2351-1 | ||
Mass (kg) | Inlet element | 4.27/5.3 | 3.4 | 9.2 | |
Middle section-General | 3.5 | / | / | / | |
Middle section-With relief valve | 5.58 | / | / | / | |
Middle section-With hydraulic operated check valve | 4.86 | / | / | / | |
Middle section hydraulic operation | / | 2.7 | 3.4 | 7.5 | |
Middle section E-H operation | / | 3.3 | 2.9 | 7.8 | |
End element | 0.27 | 3.2 | 5.7 | ||
Hydraulic | |||||
Nominal size | 6 | 9P | 09S | 18 | |
Rated flow | Q (L/min) | 60 | 90 (¦¤P=15bar£© | 90 (¦¤P=15bar£© | 180 (¦¤P=15bar£© |
Rated operating pressure at port | P /LS (bar) | 310 | / | / | / |
A/B (bar) | 310 | / | / | / | |
Max. operating pressure at port | P /LS (bar) | / | 280 | 280 | 320 |
A/B (bar) | / | 340 | 320 | 340 | |
T (bar) | / | 30 | |||
TS (bar£© | / | Less than 2 | |||
Pilot pressure | a/b (bar) | / | Less than 35 | ||
X (bar) | / | 30 | |||
Electricity | |||||
¡¤Electrical on/off£º | ¡¤Connection: Deutsch DT04-2P | ||||
¡¤Protection class: IP69k¡¤Supply voltage: 12 or 24VDC | |||||
¡¤Electrical proportional£º | ¡¤Dither frequency required: 120Hz | Electrical proportional£º | |||
¡¤Hysteresis: Less than 3% | ¡¤Dither frequency required: 100-200Hz | ||||
¡¤Connection: Deutsch DT04-2P | ¡¤Connection: Deutsch DT04-2P/AMP Junior-Timer | ||||
¡¤Protection class: IP69k | ¡¤Protection class: IP69k | ||||
¡¤Control current @12VDC: 0~1800mA, @24VDC: 0~1200mA | ¡¤Control current @12VDC£º0~1500mA; @24VDC£º0~750mA | ||||
Using environment | |||||
Hydraulic fluid | Mineral oil (HL, HLP) according to DIN 51524.Other hydraulic fluids, such as HEES (Synthetic Ester) according to VDMA 24568. | ||||
Hydraulic fluid temperature range (¡æ£© | -20 ~ +80 | -20 ~ +90 | |||
Viscosity range ¦Í (mm2/s£© | 10 ~ 380 | ||||
Maximum permissible degree of contamination of the pressure fluid cleanliness class to ISO 4406 (C) | Class 20/18/15, we therefore recommend a filter with a minimum retention rate of ¦Â10 ¡Ý 70 | Class 20/18/15, we therefore recommend a filter with a minimum retention rate of ¦Â10 ¡Ý 75 |